In 50 words: A 400 W solar panel at a good angle averages about 1.5-2.0 kWh a day in most US and Indian cities and 1.0-1.25 kWh in the UK and Germany, in PVGIS data for 22 cities. The worst month matters more: December in the north, the monsoon in India.
The usual answer to "how much does a solar panel produce per day" is a formula: panel watts times peak sun hours. It is not wrong, but it hides the two things you need to know: how many sun hours your city really gets after losses, and how far the worst month falls below the average. If you are sizing a system to cover winter, or an off-grid setup, the worst month is the number that matters.
We ran the European Commission's PVGIS 5.3 model for 22 cities in the US, Canada, the UK, Germany and India, at each city's best fixed angle with 14% system losses. Check your own city and panel count in the solar panel output calculator.
One 400 W panel, average day and extremes
| City | Average day | Best month (per day) | Worst month (per day) | Best ÷ worst | Year |
|---|---|---|---|---|---|
| Phoenix (US) | 2.01 kWh | Apr 2.31 kWh | Dec 1.68 kWh | 1.4 | 732 kWh |
| Denver (US) | 2.01 kWh | Mar 2.26 kWh | Dec 1.72 kWh | 1.3 | 734 kWh |
| Los Angeles (US) | 1.95 kWh | Aug 2.17 kWh | Dec 1.51 kWh | 1.4 | 713 kWh |
| Jaipur (India) | 1.80 kWh | Feb 2.12 kWh | Aug 1.24 kWh | 1.7 | 656 kWh |
| Delhi (India) | 1.78 kWh | Mar 2.05 kWh | Jul 1.28 kWh | 1.6 | 649 kWh |
| Miami (US) | 1.68 kWh | Apr 1.90 kWh | Dec 1.47 kWh | 1.3 | 612 kWh |
| Mumbai (India) | 1.67 kWh | Feb 2.15 kWh | Jul 0.89 kWh | 2.4 | 610 kWh |
| Bengaluru (India) | 1.66 kWh | Feb 2.14 kWh | Jul 1.24 kWh | 1.7 | 608 kWh |
| Calgary (Canada) | 1.65 kWh | Apr 2.00 kWh | Dec 1.06 kWh | 1.9 | 604 kWh |
| Chennai (India) | 1.64 kWh | Mar 1.98 kWh | Jul 1.36 kWh | 1.5 | 598 kWh |
| Houston (US) | 1.54 kWh | Apr 1.69 kWh | Dec 1.19 kWh | 1.4 | 560 kWh |
| New York (US) | 1.54 kWh | Apr 1.78 kWh | Dec 1.12 kWh | 1.6 | 562 kWh |
| Chicago (US) | 1.52 kWh | Jul 1.91 kWh | Dec 0.85 kWh | 2.2 | 556 kWh |
| Toronto (Canada) | 1.43 kWh | May 1.92 kWh | Dec 0.70 kWh | 2.7 | 523 kWh |
| Montréal (Canada) | 1.42 kWh | May 1.74 kWh | Dec 0.76 kWh | 2.3 | 520 kWh |
| Vancouver (Canada) | 1.30 kWh | Jul 1.91 kWh | Dec 0.55 kWh | 3.5 | 473 kWh |
| Seattle (US) | 1.28 kWh | Jul 1.82 kWh | Dec 0.55 kWh | 3.3 | 466 kWh |
| Munich (Germany) | 1.25 kWh | Jun 1.66 kWh | Dec 0.64 kWh | 2.6 | 456 kWh |
| Berlin (Germany) | 1.16 kWh | Jun 1.73 kWh | Dec 0.38 kWh | 4.5 | 424 kWh |
| London (UK) | 1.12 kWh | Jun 1.60 kWh | Dec 0.49 kWh | 3.3 | 409 kWh |
| Edinburgh (UK) | 1.00 kWh | May 1.51 kWh | Dec 0.32 kWh | 4.8 | 364 kWh |
| Manchester (UK) | 0.97 kWh | Jun 1.45 kWh | Jan 0.36 kWh | 4.0 | 355 kWh |
For a different panel, scale by its wattage: a 450 W panel makes 450 ÷ 400 = 1.125 times these figures. For a whole system, multiply by the number of panels.
Month by month in seven cities
Average kWh per day from one 400 W panel:
| Month | Phoenix | New York | Seattle | Toronto | London | Mumbai | Delhi |
|---|---|---|---|---|---|---|---|
| Jan | 1.82 | 1.34 | 0.66 | 0.92 | 0.55 | 2.08 | 1.88 |
| Feb | 2.04 | 1.60 | 0.99 | 1.28 | 0.78 | 2.15 | 2.02 |
| Mar | 2.22 | 1.76 | 1.29 | 1.64 | 1.13 | 2.10 | 2.05 |
| Apr | 2.31 | 1.78 | 1.56 | 1.78 | 1.53 | 1.99 | 2.02 |
| May | 2.20 | 1.67 | 1.66 | 1.92 | 1.52 | 1.78 | 1.84 |
| Jun | 2.06 | 1.66 | 1.59 | 1.86 | 1.60 | 1.21 | 1.60 |
| Jul | 1.88 | 1.67 | 1.82 | 1.82 | 1.56 | 0.89 | 1.28 |
| Aug | 1.92 | 1.63 | 1.78 | 1.75 | 1.41 | 1.06 | 1.33 |
| Sep | 2.00 | 1.56 | 1.57 | 1.52 | 1.28 | 1.28 | 1.58 |
| Oct | 2.04 | 1.37 | 1.13 | 1.08 | 0.90 | 1.73 | 1.94 |
| Nov | 1.89 | 1.32 | 0.72 | 0.92 | 0.67 | 1.88 | 1.92 |
| Dec | 1.68 | 1.12 | 0.55 | 0.70 | 0.49 | 1.94 | 1.91 |
What the numbers show
The yearly average hides a wide winter gap in the north
In Phoenix, Denver and Miami the best month makes only 1.3-1.4 times the worst. In London and Seattle it is about 3.3 times, in Berlin 4.5 and in Edinburgh 4.8. A system sized to cover your use on an average day in London covers about 44% of it on an average December day.
In India the worst months are the monsoon, not winter
Delhi, Mumbai, Chennai and Bengaluru all bottom out in July, and Jaipur in August, when cloud cover peaks. Mumbai's swing is the largest: 2.15 kWh a day in February against 0.89 kWh in July. Winter months in India are among the best.
Peak sun hours, translated
Our per-kW daily figures already include 14% system losses, so they are effectively "usable sun hours." Divide the 400 W column by 0.4 to get them: Phoenix averages about 5.0 a day, New York about 3.85, London about 2.8. If you use a peak-sun-hours figure from elsewhere, make sure it has losses taken off or your estimate will run high.
How to use these figures
- Sizing for a bill: use the year column and your annual use. Ten 400 W panels make about 5,620 kWh a year in New York.
- Sizing for winter or off-grid: use the worst month. In Toronto, covering 10 kWh a day in December takes 15 panels of 400 W (10 ÷ 0.70 = 14.3, rounded up), against 6 in May.
- Imperfect roof: multiply by your roof's share of the best angle from the tilt and direction calculator; an east or west roof typically keeps 76-86%.
- Shading: the figures assume an open sky. Shade from trees or neighbouring buildings comes off the top.
- Ageing and weather: these are averages for new panels. A year's total can swing several percent with the weather, and panels lose about 0.5% a year; the degradation calculator shows both for your city.
How we modelled it
PVGIS 5.3 PVcalc runs for 1 kW of crystalline silicon panels at each city's PVGIS optimum fixed tilt and direction, 14% system losses, radiation data PVGIS-SARAH3 for the UK and Germany and PVGIS-ERA5 for the US, Canada and India. Monthly figures are PVGIS's average daily output for each month over its multi-year record. Retrieved November 10, 2026.
Related
Sources
Researched and drafted by the Earth Energy Log Editorial Desk with AI assistance. Reviewed by Pruthvi A. before publication.
How we work: Editorial standards · AI disclosure · Report an error