Skip to content
Solar PV · Policy & Tenders · Analysis

Plug-in balcony solar in the UK and Germany: what 800 W really saves

800 W of plug-in panels on a south-facing balcony make about 515-670 kWh a year in UK and German cities, in hourly PVGIS data. Savings depend on how much your home uses as it is made: at a 200 W baseload about £100-110 a year in the UK and €160-170 in Germany.

Reviewed by Pruthvi A. · 5 min read
Two installers fitting solar panels on a tiled roof
Photo: rawpixel (CC0)

In 50 words: 800 W of plug-in panels on a south-facing balcony make about 515-670 kWh a year in UK and German cities, in hourly PVGIS data. Savings depend on how much your home uses as it is made: at a 200 W baseload about £100-110 a year in the UK and €160-170 in Germany.

Plug-in solar, the panels you hang on a balcony railing or stand in a garden and plug into a socket, became legal to buy and use in Great Britain in 2026 under a new government product specification. Germany allows them under its Renewable Energy Sources Act, where they are called Steckersolargeräte or, popularly, Balkonkraftwerke. Both countries now share the same core limits: up to 800 VA into the home's wiring and up to 2,000 W of panels.

Most savings figures online come from retailers and assume you use every kWh. You won't, because the panels produce most around midday, when many homes draw little. We worked out output and the share a home actually uses, hour by hour, from four years of PVGIS data for London, Manchester, Edinburgh, Munich and Berlin. Check your own set-up in the plug-in solar calculator.

The rules

Great BritainGermany
Power into the home's wiringUp to 800 VA (3.5 A)Up to 800 VA
Panel powerUp to 2,000 W; professional check advised above 960 WUp to 2 kW
Number of devicesOne per household under G98, until amendedTotal limits apply to all devices
Payment for surplus fed into the gridDepends on supplierNone: assigned to unpaid acceptance
RegistrationG98 notification to the network operatorMarktstammdatenregister
Where not to mountTimber balconies, certain cladding, buildings under fire-safety remediationFollow manufacturer and building rules

Sources: the government's interim product specification for Great Britain and § 8 (5a) of Germany's Renewable Energy Sources Act (EEG).

What 800 W makes and saves

800 W of panels, 200 W baseload, savings at the UK price cap (26.32p/kWh) or Germany's Destatis average (37.97 ct/kWh):

CityMountingOutput per yearUsed at homeSaving per year
LondonVertical, facing south588 kWh416 kWh (71%)£109
London30° stand, facing south812 kWh511 kWh (63%)£134
LondonVertical, facing east422 kWh313 kWh (74%)£82
ManchesterVertical, facing south516 kWh376 kWh (73%)£99
EdinburghVertical, facing south545 kWh389 kWh (71%)£102
MunichVertical, facing south666 kWh446 kWh (67%)€169
Munich30° stand, facing south930 kWh540 kWh (58%)€205
BerlinVertical, facing south606 kWh419 kWh (69%)€159
Berlin30° stand, facing south840 kWh509 kWh (61%)€193

Three things stand out:

  • A stand beats a railing. Tilting the same panels to 30 degrees adds about 40% output, but self-use rises less, because the extra comes in the sunniest hours.
  • Germany saves more per kWh. The same output is worth more at 37.97 ct than at 26.32p, so the same kit pays back faster at German prices.
  • East or west costs output but wastes less. An east-facing kit in London makes 28% less than a south-facing one but uses a higher share at home, because its output is spread across the morning.

Your baseload decides the saving

Baseload is what your home draws with nothing switched on: fridge, freezer, router, standby devices. It is the part of a plug-in kit's output you are certain to use. For 800 W on a south-facing railing in London:

BaseloadUsed at home per yearSaving at 26.32p
100 W265 kWh£70
200 W416 kWh£109
400 W562 kWh£148

A smart meter's overnight reading is the easiest way to see your baseload. Running the washing machine or dishwasher in sunny hours adds to self-use beyond these figures.

Is 2,000 W of panels worth it?

Both countries allow up to 2,000 W of panels behind the 800 VA limit, and kits of that size are widely sold. More panels do produce more on dull days, but on sunny days they hit the cap.

On a vertical south railing in London, 2,000 W of panels make 1,308 kWh a year, about 2.2 times the output of 800 W, with 11% lost to the cap. But at a 200 W baseload, self-use rises only from 416 kWh to 561 kWh, about 35% more, and the saving from about £109 to £148. The rest is exported; in Germany that earns nothing. On a 30-degree south-facing stand the cap takes 15-22% of a 2,000 W kit's output, most in Munich.

Larger kits pay most for homes with a high daytime baseload, or where surplus is paid for. In the UK, the specification also advises a professional check of your wiring above 960 W.

Before you buy

  1. Check the mounting is allowed: not on timber balconies or certain cladding in Great Britain, and with the landlord's or building's consent where needed.
  2. Measure your baseload from a smart meter or plug-in energy monitor.
  3. Face south if you can, and prefer a tilted stand to a vertical railing where space allows.
  4. Register or notify: G98 notification in Great Britain, the Marktstammdatenregister in Germany.
  5. Enter your kit price in the calculator to see the payback.

How we modelled it

PVGIS 5.3 hourly output for 2020-2023 (PVGIS-SARAH3), 14% system losses, scaled to the panel power and capped at 800 VA in each hour. Self-use is the lower of each hour's output and a constant baseload. Retrieved November 10, 2026. Real household demand varies through the day, so treat self-use as an estimate for a home with that steady background load.

Free toolEstimate your solar system size, cost and paybackOpen solar calculator →

Sources

  1. DESNZ, Plug-in Solar Device Interim Product Specification v2.0 (July 2026)
  2. DESNZ, Plug-in solar: regulatory amendment and interim product specification, government response (July 2026)
  3. EEG 2023, § 8 (5a): Steckersolargeräte
  4. Destatis, household electricity prices, first half of 2026 (press release no. 345)
  5. European Commission Joint Research Centre, PVGIS 5.3 hourly series
EE
About the authorEarth Energy Log Editorial DeskArticles are researched and drafted by the Earth Energy Log desk with AI assistance, checked against primary sources, and reviewed by a named editor before publication.More from Earth Energy Log Editorial Desk →

Researched and drafted by the Earth Energy Log Editorial Desk with AI assistance. Reviewed by Pruthvi A. before publication.

How we work: Editorial standards · AI disclosure · Report an error

More in Solar PV

Newsletter

The weekly brief

Every Tuesday: the 5 stories that matter, India tender awards roundup, one chart we made. Free.