Solar panel tilt and direction calculator
Most guides give one number for an east or west roof. The real loss depends on where you live and how steep the roof is: in our PVGIS data a 30-degree west roof keeps 86% of the best output in Mumbai but 67% in Chicago. Pick the nearest city, your roof's tilt and direction, and see what you keep.
Pick the closest city at a similar latitude and climate.
0 is flat, 90 is vertical (a wall or balcony rail). A 6/12 roof pitch is about 27 degrees.
True compass direction, not magnetic.
Your roof vs the best angle
- Output vs the best fixed angle
- 99%
- Output lost to tilt and direction
- 1%
- Yearly output per kW
- 1,392 kWh
- Yearly output for your system (5 kW)
- 6,960 kWh
- Best fixed angle here
- 38° facing S (1,405 kWh/kW)
- Best tilt for your direction
- 38° (100%)
- A flat array gives
- 82%
PVGIS modelled yield with 14% system losses and no local shading. Trees, chimneys and nearby buildings can cut output more than direction does.
Defaults and sources
- Solar yield by tilt and direction
- PVGIS 5.3 modelled annual output per kW for 22 cities, 7 tilts and 8 directions, with 14% system losses; radiation data PVGIS-SARAH3 for the UK and Germany, PVGIS-ERA5 for the US, Canada and IndiaEuropean Commission Joint Research Centre, PVGIS 5.3 · checked Nov 10, 2026
How the calculator works
For each city we ran the EU Joint Research Centre's PVGIS 5.3 model for 1 kW of crystalline silicon panels with 14% system losses at 7 tilts (10 to 90 degrees) and 8 compass directions, plus a flat array and PVGIS's optimum fixed angle: 1,276 runs in all.
Your result interpolates between the modelled tilts for your direction and divides by the optimum angle's output. The best tilt for your direction scans that interpolated curve in 1-degree steps. Results assume no local shading.
Solar panel tilt and direction: common questions
How much do east- or west-facing solar panels lose?
At a 30-degree tilt, east or west roofs in our 22 cities keep 67-91% of the best fixed angle's output, most often 76-86%. Lowering the tilt helps: at 10 degrees they keep 77-97%. West roofs in Chicago and Toronto do worst, at 67%.
What is the best tilt angle for solar panels?
PVGIS's optimum is usually a little below your latitude: about 38 degrees in New York and Toronto, 40 in London and Berlin, 32 in Delhi and 15-17 in Chennai and Bengaluru. A few degrees either side costs little: a 30-degree south roof keeps 96-100% everywhere we modelled.
Are flat-mounted solar panels worth it?
Near the equator, yes: a flat array keeps 97-98% of the best output in Chennai and Bengaluru. Further north it keeps 74-84% in Canada, the northern US, the UK and Germany, so a low tilt frame usually pays off there.
How much do vertical or balcony solar panels produce?
A vertical south-facing panel keeps 73-75% of the best output in London, Manchester and Edinburgh and 76% in Calgary, because the sun is low for much of the year. Near the equator it falls to 42-44% (Chennai, Bengaluru).
Is a north-facing roof worth it for solar?
Rarely in the north. A 30-degree north roof keeps 43-60% of the best output in Canada, the northern US, the UK and Germany. In southern India it keeps 76-78%, because the sun passes close to overhead.