East- or west-facing solar panels: how much output you lose, city by city

In PVGIS runs for 22 cities, east- or west-facing panels at 30 degrees keep 67-91% of the best fixed angle's output, most often 76-86%. Lowering the tilt to 10 degrees recovers most of the loss. West roofs in Chicago and Toronto fare worst; in southern India direction barely matters.

Reviewed by Pruthvi A. · 7 min read
Two installers fitting solar panels on a tiled roof
Photo: rawpixel (CC0)

In 50 words: In PVGIS runs for 22 cities, east- or west-facing panels at 30 degrees keep 67-91% of the best fixed angle's output, most often 76-86%. Lowering the tilt to 10 degrees recovers most of the loss. West roofs in Chicago and Toronto fare worst; in southern India direction barely matters.

"East- and west-facing panels lose 10-20%" is the line most guides repeat. It is roughly right in some places and wrong in others, because the loss depends on latitude, local weather and how steep the roof is. To replace the rule of thumb with numbers, we ran the European Commission's PVGIS 5.3 solar model 1,276 times: 22 cities in the US, Canada, the UK, Germany and India, 7 tilts and 8 compass directions each.

Every figure below is the output of 1 kW of crystalline silicon panels with 14% system losses, as a share of the best fixed angle at that city. To check your own roof, use the solar panel tilt and direction calculator.

The full table

Cities run from the equator northwards. "Best tilt" and "best output" are PVGIS's optimum fixed angle at that location.

CityBest tiltBest output (kWh/kW)South 30°East 30°West 30°East 10°West 10°FlatVertical southNorth 30°
Bengaluru (India)17°1,51998%91%89%97%95%97%44%76%
Chennai (India)15°1,49497%90%91%97%97%98%42%78%
Mumbai (India)25°1,525100%86%86%92%92%93%52%66%
Miami (US)26°1,529100%88%84%92%91%92%52%66%
Jaipur (India)31°1,640100%84%81%88%87%88%59%57%
Delhi (India)32°1,623100%83%81%87%86%88%60%56%
Houston (US)28°1,401100%86%84%91%90%91%56%63%
Phoenix (US)33°1,831100%82%80%86%85%86%61%54%
Los Angeles (US)32°1,782100%81%82%86%87%87%60%55%
Denver (US)40°1,83498%80%73%81%78%80%69%47%
New York (US)38°1,40599%79%76%82%81%82%68%51%
Chicago (US)38°1,39297%85%67%86%78%83%63%53%
Toronto (Canada)38°1,30797%84%67%85%77%82%64%53%
Montréal (Canada)39°1,30099%76%77%81%81%82%69%51%
Seattle (US)39°1,16699%76%79%81%82%82%69%51%
Munich (Germany)39°1,14199%80%79%83%83%83%71%56%
Vancouver (Canada)40°1,18399%77%78%80%81%81%70%50%
Calgary (Canada)47°1,50996%74%69%74%72%74%76%43%
London (UK)40°1,02399%81%78%83%82%83%73%57%
Berlin (Germany)40°1,06199%80%78%82%82%82%72%55%
Manchester (UK)39°88899%82%80%84%83%84%73%60%
Edinburgh (UK)42°90998%79%78%81%80%81%75%56%

What the numbers show

East or west roofs keep most of their output

At a common 30-degree pitch, east or west roofs keep 76-86% of the best output in most cities. The rule-of-thumb "10-20% loss" fits the warm, low-latitude cities; in the northern US, Canada, the UK and Germany the loss is usually 18-24%.

The exceptions matter. In PVGIS's data for Chicago and Toronto, a west roof keeps only 67% while an east roof keeps 84-85%; Denver shows the same pattern, less strongly (73% west, 80% east). If you have a choice of roof faces in those cities, east is the better one.

A shallower tilt recovers most of the loss

East- and west-facing panels lose less the flatter they lie, because a flat panel does not care which way it points. At 10 degrees, east or west arrays keep 72-97% of the best output, a few points more than at 30 degrees in most cities and up to 11 points more for west roofs in Chicago and Toronto. On a low-pitch roof or a flat roof with east-west racking, that is the main design lever.

Near the equator, direction hardly matters

In Chennai and Bengaluru the sun passes close to overhead, so a flat array keeps 97-98% of the best output and even a 30-degree north roof keeps 76-78%. The best tilt there is 15-17 degrees. Further north the penalty for the wrong direction grows: a north roof keeps only 43-60% in Canada, the northern US, the UK and Germany.

Vertical panels work better the further north you are

A vertical, south-facing panel, as on a wall, fence or balcony railing, keeps 73-75% of the best output in London, Manchester and Edinburgh. In Calgary it keeps 76%, more than a flat panel there (74%), because the sun is low in the sky for much of the year. Near the equator a vertical panel keeps only 42-44%.

What it means for cost per kWh

Output share translates directly into the cost of each unit you generate. A roof that keeps 80% of the best output makes each kWh about 25% more expensive than an ideal roof for the same installed price (1 ÷ 0.8 = 1.25). At 67%, each kWh costs about 50% more.

That does not make an east or west roof a bad investment: in most places a 76-86% roof still pays back, just more slowly. Run the payback with your real output in the solar calculator, using the kWh per kW from the tilt and direction calculator.

Practical choices for an imperfect roof

  1. Use both faces of an east-west roof. Each face keeps 76-86% of the best output in most cities, and together they spread generation across the morning and the evening instead of peaking at midday.
  2. Prefer east over west in Chicago, Toronto and Denver. PVGIS's data shows west roofs there losing far more than east roofs.
  3. Go shallow on a flat roof. Low-tilt east-west racking keeps most of the output and fits more panels in the same space. If you use equator-facing rows instead, see how far apart solar panel rows should be for your latitude.
  4. Skip north faces above about 40 degrees latitude. At 43-60% of the best output, they rarely pay.
  5. Consider vertical panels in the far north. In the UK and Calgary they keep 73-76% of the best output.
  6. Check shading first. The table assumes an open sky. A tree or chimney shading the panels for part of the day can cost more than the wrong direction.

How we modelled it

We used PVGIS 5.3's PVcalc service for each city's coordinates with its default radiation database: PVGIS-SARAH3 for the UK and Germany and PVGIS-ERA5 for the US, Canada and India. Each run modelled 1 kW of crystalline silicon panels with 14% system losses at tilts of 10, 20, 30, 40, 50, 60 and 90 degrees and eight compass directions, plus a flat array and PVGIS's own optimum angle. The data was retrieved on November 10, 2026.

Free toolEstimate your solar system size, cost and paybackOpen solar calculator →

Sources

  1. European Commission Joint Research Centre, PVGIS 5.3 (PVcalc API)
EE
About the authorEarth Energy Log Editorial DeskArticles are researched and drafted by the Earth Energy Log desk with AI assistance, checked against primary sources, and reviewed by a named editor before publication.More from Earth Energy Log Editorial Desk →

Researched and drafted by the Earth Energy Log Editorial Desk with AI assistance. Reviewed by Pruthvi A. before publication.