In 50 words: Each kWh of US rooftop solar avoids 0.11 to 0.70 kg of CO2e at EPA's 2023 average grid rates, depending on the region, and more at non-baseload rates. Making the panels emits about 1,127 kg per kW, so a typical system repays its carbon in roughly one to four years.
Online solar carbon calculators disagree wildly, often because they use a single national factor or a state's own power plants. We used the EPA's grid emission rates for each of its 27 eGRID subregions and the international life cycle figures from IEA PVPS, and worked out how fast panels repay the emissions of making them. Try your own system in the solar CO2 savings calculator.
Why grid region, not state
States trade electricity, so the power a home uses is not the power its state generates. Vermont's own power plants emitted 52 lb of CO2e per MWh in 2023, according to eGRID, but the New England grid it draws from averaged 543 lb. EPA therefore recommends its subregion rates for estimating emissions from electricity use. You can find your subregion from your ZIP code with EPA's Power Profiler.
eGRID gives two rates per subregion. The total output rate averages all generation. The non-baseload rate covers the plants that vary their output through the day and year, which are closer to what new solar displaces. We show both.
What making the panels emits
IEA PVPS Task 12 puts the life cycle emissions of a residential mono-crystalline silicon rooftop system at 42.9 g of CO2e per kWh. That covers manufacturing, transport, installation, use and end of life, for a system in Europe producing 975 kWh per kWp a year for 30 years with 0.7% yearly degradation. Multiplied back out, that is about 1,127 kg of CO2e per kW of panels: about 8.1 t for a 7.2 kW home system.
Emissions avoided and carbon payback by region
Carbon payback is the time the panels take to avoid as much CO2e as making them emitted. It scales with your output: a system producing 1,500 kWh per kW a year pays back two-thirds as long as the figure below, which is for 1,000 kWh per kW.
| eGRID subregion | Average (kg CO2e/kWh) | Non-baseload (kg CO2e/kWh) | Carbon payback per 1,000 kWh/kW a year, average / non-baseload |
|---|---|---|---|
| PRMS (Puerto Rico Miscellaneous) | 0.70 | 0.74 | 19 / 18 months |
| HIOA (HICC Oahu) | 0.68 | 0.80 | 20 / 17 months |
| MROE (MRO East) | 0.64 | 0.78 | 21 / 17 months |
| SRMW (SERC Midwest) | 0.57 | 0.83 | 24 / 16 months |
| NYLI (NPCC Long Island) | 0.54 | 0.60 | 25 / 23 months |
| HIMS (HICC Miscellaneous) | 0.51 | 0.73 | 26 / 19 months |
| RMPA (WECC Rockies) | 0.47 | 0.74 | 29 / 18 months |
| RFCM (RFC Michigan) | 0.44 | 0.69 | 31 / 20 months |
| MROW (MRO West) | 0.42 | 0.81 | 32 / 17 months |
| RFCW (RFC West) | 0.42 | 0.80 | 33 / 17 months |
| AKGD (ASCC Alaska Grid) | 0.41 | 0.49 | 33 / 27 months |
| SRTV (SERC Tennessee Valley) | 0.41 | 0.76 | 33 / 18 months |
| SPSO (SPP South) | 0.40 | 0.67 | 34 / 20 months |
| SPNO (SPP North) | 0.39 | 0.86 | 34 / 16 months |
| NYCW (NPCC NYC/Westchester) | 0.39 | 0.44 | 34 / 30 months |
| SRSO (SERC South) | 0.38 | 0.63 | 35 / 21 months |
| FRCC (FRCC All) | 0.36 | 0.45 | 38 / 30 months |
| SRMV (SERC Mississippi Valley) | 0.34 | 0.52 | 40 / 26 months |
| ERCT (ERCOT All) | 0.33 | 0.57 | 40 / 24 months |
| AZNM (WECC Southwest) | 0.32 | 0.53 | 42 / 25 months |
| NWPP (WECC Northwest) | 0.29 | 0.74 | 47 / 18 months |
| RFCE (RFC East) | 0.27 | 0.54 | 50 / 25 months |
| SRVC (SERC Virginia/Carolina) | 0.27 | 0.59 | 50 / 23 months |
| NEWE (NPCC New England) | 0.25 | 0.40 | 55 / 34 months |
| AKMS (ASCC Miscellaneous) | 0.24 | 0.70 | 57 / 19 months |
| CAMX (WECC California) | 0.20 | 0.44 | 69 / 31 months |
| NYUP (NPCC Upstate NY) | 0.11 | 0.41 | 123 / 33 months |
Three example systems
A 7.2 kW system, the median US home system size in 2024 according to Berkeley Lab, with PVWatts output for each state:
- Missouri (SERC Midwest, 1,433 kWh per kW): avoids 5.8 to 8.6 t of CO2e a year and repays its carbon in 11 to 17 months.
- Texas (ERCOT, 1,421 kWh per kW): avoids 3.4 to 5.8 t a year; payback 17 to 28 months.
- Massachusetts (New England, 1,302 kWh per kW): avoids 2.3 to 3.8 t a year; payback 26 to 42 months.
In each case the first figure uses the average rate and the second the non-baseload rate. Over 25 years at 0.5% yearly degradation, the Texas system avoids a net 72 to 128 t after its own emissions, about the same as not driving 8,500 to 14,500 miles a year at EPA's 400 g of CO2 per mile for the average car.
What the figures leave out
- A cleaner future grid. As more wind, solar and storage join a region, each kWh of new solar displaces less. Figures for later years will be lower than these 2023 rates.
- Where your panels were made. IEA PVPS's figure is for a European-average supply chain; panels made with more coal power carry more embodied carbon.
- Batteries. A home battery adds its own manufacturing emissions and losses, and shifts when your solar power is used.
- Detailed dispatch. For large projects EPA's AVERT tool models which plants solar actually displaces hour by hour.
Frequently asked questions
How much CO2 does a solar panel system save per year?
For a 7.2 kW home system, about 2.3 t of CO2e a year in Massachusetts (New England grid) and 5.8 t in Missouri (SERC Midwest) at EPA's 2023 average rates, and more at non-baseload rates (3.8 and 8.6 t). Your grid region matters more than your panels.
What is the carbon footprint of solar panels?
IEA PVPS puts it at 42.9 g of CO2e per kWh for a residential mono-Si rooftop system over 30 years in Europe, or about 1,127 kg per kW of panels. That is below the 2023 average rate of every US grid region, which ranged from 0.11 to 0.70 kg per kWh.
How long does it take solar panels to pay back their carbon?
Roughly one to four years for most US homes: 11 to 17 months in Missouri, 17 to 28 months in Texas and 26 to 42 months in Massachusetts for a 7.2 kW system, depending on whether you use the average or non-baseload rate.
Why do solar carbon calculators give different answers?
They use different emission factors: national averages, state generation rates or regional rates, and either average or non-baseload figures. Some also ignore the panels' own emissions. EPA recommends regional (subregion) rates for electricity use.
Related
Sources
Researched and drafted by the Earth Energy Log Editorial Desk with AI assistance. Reviewed by Pruthvi A. before publication.
How we work: Editorial standards · AI disclosure · Report an error