Panels lose a little output every year, but weather moves a year's total far more. In PVGIS data for 2005-2023, Munich's worst year was 11% below its average; ten years of ageing at NREL's 0.5% median costs about 5%. Enter your system and this year's output to see the warranty floor, what field data says to expect, and whether a shortfall is likely to be weather.
Sets the average output per kW and how much a normal year swings.
Panel wattage times the number of panels, divided by 1,000.
Leave at 0 to use PVGIS for your city at the best angle with 14% losses. Enter your installer's first-year estimate if you have one.
From the manufacturer's datasheet. Pick Other to enter your own terms.
1 = the first 12 months after switch-on.
From your inverter app or generation meter. Leave at 0 to skip the check.
Your import rate, to value the energy lost to ageing. Leave at 0 to skip.
Your system over time
- Expected output when new (average weather)
- 8,430 kWh
- Warranty floor this year (8)
- 96.3% = 8,114 kWh
- Expected at NREL's 0.5%/yr field median
- 96.5% = 8,135 kWh
- Normal weather range this year (2 standard deviations)
- 7,679 kWh - 8,591 kWh
- Worst single year here since 2005 (2018)
- -7.2%
Warranties cover module power measured under standard test conditions, not your meter. System output also falls with soiling, shading, inverter faults and wiring, and rises or falls several percent with the weather.
Energy over the period (25 years)
- With no degradation
- 210,750 kWh
- At the warranty floor
- 200,213 kWh (95.0%)
- At 0.5% a year (NREL field median)
- 198,105 kWh (94.0%)
- At 0.75% a year (NREL US fleet)
- 191,783 kWh (91.0%)
Output by year, % of expected when new
- Year
- Warranty floor · 0.5%/yr · 0.75%/yr · 0.88%/yr (hot)
- 1
- 98.0% · 100.0% · 100.0% · 100.0%
- 5
- 97.0% · 98.0% · 97.0% · 96.5%
- 10
- 95.8% · 95.5% · 93.3% · 92.1%
- 15
- 94.5% · 93.0% · 89.5% · 87.7%
- 20
- 93.3% · 90.5% · 85.8% · 83.3%
- 25
- 92.0% · 88.0% · 82.0% · 78.9%
Defaults and sources
- Median field degradation (literature review)
- 0.5% per year: median of nearly 2,000 degradation rates measured on modules and systems in the fieldJordan and Kurtz, Photovoltaic Degradation Rates - An Analytical Review (NREL/JA-5200-51664, Progress in Photovoltaics) · checked Nov 15, 2026
- US fleet performance loss
- 0.75% per year overall (7.2 GW, 1,700 sites); 0.48% per year in cooler climates, 0.88% per year in hotter climatesJordan et al., Photovoltaic fleet degradation insights (NREL, Progress in Photovoltaics 2022) · checked Nov 15, 2026
- REC Alpha Pure-RX performance warranty
- 98% of nameplate in year 1, then at most 0.25% a year; 92% in year 25REC Alpha Pure-RX datasheet (US) · checked Nov 15, 2026
- Jinko Tiger Neo linear power warranty
- 30-year linear power warranty, 0.40% annual degradation (15-year product warranty)JinkoSolar Tiger Neo 54HL4R-(V) 425-445 W datasheet · checked Nov 15, 2026
- Jinko Tiger Neo first-year degradation
- At most 1% in the first year, then 0.4% a year (87.4% in year 30 by the warranty formula)JinkoSolar, Tiger Neo product page · checked Nov 15, 2026
- Year-to-year variation in solar output
- Average yearly output, its standard deviation, and the worst and best year, per city (PVGIS 5.3, optimum angle, 14% losses)European Commission Joint Research Centre, PVGIS 5.3 (PVcalc and seriescalc) · checked Nov 15, 2026
How the calculator works
Expected output when new is PVGIS 5.3's average yearly output for your city (optimum fixed angle, 14% system losses, weather 2005-2023) times your system size, unless you enter your own estimate.
The warranty floor for year n is the guaranteed year-1 percentage minus the annual allowance for each year after the first, the formula manufacturers use (REC: 98% minus 0.25% a year reaches 92% in year 25). Field curves start at 100% and lose a fixed share each year: 0.5% (NREL's median of nearly 2,000 field rates), 0.75% (NREL's US fleet of 1,700 commercial and utility sites) and 0.88% (that study's hotter-climate median).
The weather range is two standard deviations of PVGIS's year-to-year output around the 0.5% curve for this year. A reading below the warranty floor and below that range is unlikely to be weather alone.
Solar panel degradation: common questions
How much do solar panels degrade per year?
About 0.5% a year is typical. NREL's review of nearly 2,000 field measurements found a median of 0.5% per year, and its 2022 study of 1,700 US commercial and utility sites found 0.75% per year for whole systems, 0.48% in cooler climates and 0.88% in hotter ones. Warranties on current panels allow 0.25-0.4% a year after the first year.
How much power will my panels have after 25 years?
At NREL's 0.5% median, about 88% of the output when new. The warranty floor is usually lower or similar: REC Alpha Pure-RX guarantees 92% in year 25, and Jinko Tiger Neo's formula (99% in year 1, then 0.4% a year) gives 89.4% in year 25 and 87.4% in year 30.
My solar output is down this year. Is it degradation?
Usually it is weather. In PVGIS data for 2005-2023 a normal year swings by 1.3-5.8% (one standard deviation) depending on the city, and the worst single year was 6% below average in London and 11% below in Munich. Degradation at 0.5% a year takes a decade to cost 5%. Compare several years, or the same months against a neighbour's system.
How do I make a solar panel warranty claim?
The warranty covers the module's power under standard test conditions, so the manufacturer will want a flash test or measured I-V curves, not your app's yearly total. First rule out shading, dirt, inverter faults and failed strings, then ask your installer to test the modules against the datasheet rating and the warranty floor for their age.