Skip to content
Free tools

Off-grid solar system calculator

Off-grid systems fail in the worst month, not the average one. In our PVGIS data, covering 10 kWh a day through December takes 22 panels of 400 W in London against 10 for the yearly average; in Mumbai the hard month is the July monsoon. Enter your daily use to size the array, battery and the months you will run short or spill power.

Pick the closest city at a similar latitude and climate.

Add up appliance watts x hours used, or take your bill's monthly kWh / 30.

This part goes through the battery and loses some energy on the way.

From the battery or inverter datasheet; the default is an assumption, so replace it with your system's figure.

How many days of use the battery should cover with no sun. More days means a bigger battery.

Your off-grid system

Solar needed per day (incl. battery losses)
10.7 kWh
Worst month
Dec (2.80 kWh/kW/day)
Array size for the worst month
3.81 kW
Panels (400 W)
10
Array size for an average month (for comparison)
2.77 kW (7 panels)
Extra array for winter vs average
1.37x
Usable battery capacity
20.0 kWh

PVGIS monthly averages at the best fixed angle with 14% losses. Individual cloudy weeks fall well below the monthly average, which is what the battery days cover. Most off-grid homes also keep a generator.

Each month at this array size (kWh per day)

Jan
+2.1 kWh surplus
Feb
+4.6 kWh surplus
Mar
+6.1 kWh surplus
Apr
+6.2 kWh surplus
May
+5.2 kWh surplus
Jun
+5.2 kWh surplus
Jul
+5.3 kWh surplus
Aug
+4.8 kWh surplus
Sep
+4.2 kWh surplus
Oct
+2.4 kWh surplus
Nov
+1.9 kWh surplus
Dec
+0.0 kWh surplus

Defaults and sources

Daily output by month
PVGIS 5.3 average daily output per kW for each month at the optimum fixed angle, 14% system losses, 22 cities; PVGIS-SARAH3 for the UK and Germany, PVGIS-ERA5 elsewhereEuropean Commission Joint Research Centre, PVGIS 5.3 · checked Nov 10, 2026

How the calculator works

Solar needed per day is the daytime share of your use plus the night share divided by the battery's round-trip efficiency. The array size is that figure divided by your city's lowest monthly PVGIS output per kW per day; panels are the array size divided by panel watts, rounded up.

Usable battery capacity is your daily use times the days of autonomy. The month table multiplies each month's PVGIS output per kW by the array size and compares it with the solar needed per day.

Off-grid solar sizing: common questions

How many solar panels do I need to go off grid?

Enough for your worst month. For 10 kWh a day with 60% used at night through a 90%-efficient battery, our PVGIS data gives 7 panels of 400 W in Phoenix, 9 in Delhi, 10 in New York, 16 in Toronto, 20 in Seattle and 22 in London.

Why size for the worst month instead of the average?

Because the average month leaves you short every winter (or monsoon). Sizing for the worst month needs 1.2 times the average-month array in Phoenix, about 1.4 in New York and Delhi, 1.9 in Mumbai, 2.0 in Toronto and 2.3 in London and Seattle.

How big a battery do I need off grid?

Daily use times the days you want to ride through without sun. Two days at 10 kWh a day is 20 kWh of usable capacity; check the battery's usable rating, not its total. The battery covers cloudy spells; the array size covers the season.

Which month is worst for off-grid solar in India?

July, in our data for Delhi, Mumbai, Chennai and Bengaluru, and August in Jaipur: the monsoon, not winter. Mumbai's July output is 41% of its best month, February.

Related

Newsletter

The weekly brief

Every Tuesday: the 5 stories that matter, India tender awards roundup, one chart we made. Free.

No spam. Unsubscribe in one click.