Skip to content
Free tools

Solar and battery calculator Victoria (2026)

On the 2026-27 Victorian Default Offer, a Melbourne home using 4,000 kWh a year pays about $1,481 on CitiPower's flat tariff. A 6.6 kW solar system cuts that to about $1,056, saving $424 a year if your retailer pays no feed-in tariff, and a 13.5 kWh battery saves about $604 a year more. There has been no minimum feed-in tariff since 1 July 2025, so what your retailer pays for exports changes the answer. Enter your distributor, usage, system and quotes.

Your home

Sets the hour-by-hour solar output from PVGIS for 2019-2023 and the STC zone for the solar rebate.

Your distributor is named on your bill. It sets the Victorian Default Offer prices used here.

Tariff

Time of use: peak 4-9 pm, solar soak 11 am-4 pm, off-peak all other hours, every day.

Add up four quarterly bills. 4,000 kWh is the ESC's representative home.

The ESC's reference split for Victorian homes is 29% in the peak, 18% in the solar soak and 53% off-peak. A time-of-use bill shows yours.

Raise this if someone is home during the day: daytime use is what solar covers directly.

Solar and battery

Panels' rated power. Modelled north-facing at 25 degrees with 14% system losses.

Set to 0 to see solar on its own. The battery charges only from surplus solar and runs the house when the sun is not enough.

Share of stored energy you get back. Check the battery's datasheet.

Sets the federal solar and battery rebates: both drop on 1 January 2027.

Feed-in tariff and quotes

There is no minimum since 1 July 2025: retailers set their own, and it cannot be below zero. Use your retailer's rate.

The full installed price before the STC discount.

The full installed price of the battery before the Cheaper Home Batteries discount.

The clearing house price is $40; installers often pass on a little less.

Your bills and payback

Bill now (no solar)
$1,481
Bill with solar
$1,056
Bill with solar and battery
$452
Solar saves
$424 a year
Battery adds
$604 a year
Usage met by solar and battery
99%
Solar exported
4,921 kWh a year
Federal solar rebate (39 STCs)
$1,560
Federal battery rebate (91 STCs)
$3,640
Solar payback
Enter a quote
Battery payback (on its own saving)
Enter a quote

Prices are the Essential Services Commission's 2026-27 Victorian Default Offer, including GST. Many market offers are cheaper or dearer: change the tariff to match your bill. Payback is the cost after federal rebates divided by the first-year saving, with no price rises or panel degradation.

  • Each 1c of feed-in tariff is worth about $75 a year with solar alone, and $49 with the battery.
  • Usage is spread evenly within each period and is the same every day. Homes that use more in winter, heat with electricity or charge an EV will import more than shown.
Flat or time of use?
SetupFlatTime of use
No solar$1,481$1,455
Solar$1,056$1,076
Solar and battery$452$451

Annual bill on each 2026-27 Victorian Default Offer tariff for your distributor.

What each battery size adds
Usable kWhExtra saving a yearFederal rebatePayback
5$417$1,360—
10$594$2,720—
13.5$604$3,640—
20$611$4,760—
30$613$6,160—

With your solar system, tariff and feed-in tariff. Payback uses the federal rebate for each size and your battery quote per kWh, when you enter one.

Defaults and sources

Electricity prices (Victorian Default Offer 2026-27)
Flat and three-period time-of-use domestic tariffs by distribution zone, including GST, 1 July 2026 to 30 June 2027Essential Services Commission, Victorian Default Offer (2026-27 tariffs) · checked Nov 24, 2026
Default usage and its timing
4,000 kWh a year; 29% in the 4-9 pm peak, 53% off-peak (9 pm-11 am), 18% in the 11 am-4 pm solar soak (ESC reference proportions from AEMO residential load)Essential Services Commission, Victorian Default Offer 2026-27 Final Decision Paper (20 May 2026), representative usage and Table D.2 · checked Nov 24, 2026
Feed-in tariff
No minimum feed-in tariff since 1 July 2025: retailers set their own, and it cannot be below zeroEssential Services Commission, Minimum feed-in tariff · checked Nov 24, 2026
Solar output by hour
PVGIS (ERA5) hourly output 2019-2023 for 8 Victorian cities, north-facing at 25 degrees, 14% system loss; Melbourne about 1,386 kWh per kW a yearEuropean Commission JRC, PVGIS 5.3 hourly radiation and PV data · checked Nov 24, 2026
Postcode zones and zone ratings
Zone 1: 1.622, zone 2: 1.536, zone 3: 1.382, zone 4: 1.185 MWh per kW a year, by postcode range (137 ranges)Clean Energy Regulator, Postcode zone ratings and zones for solar (photovoltaic) systems (as of 1 January 2020) · checked Nov 24, 2026
Years counted (deeming period)
By the year the system is first able to produce and deliver electricity: 2026 5 years, 2027 4, 2028 3, 2029 2, 2030 1Renewable Energy (Electricity) Regulations 2001, reg 19D; Clean Energy Regulator, Calculate STC entitlements · checked Nov 24, 2026
STC factor per usable kWh
6.8 for batteries certified 1 May to 31 Dec 2026; 5.7 (Jan-Jun 2027), 5.2 (Jul-Dec 2027), 4.6, 4.1 (2028), 3.6, 3.1 (2029), 2.6, 2.1 (2030). Before 1 May 2026: 9.3 in 2025 and 8.4 from 1 Jan 2026Renewable Energy Legislation Amendment (2026 Measures No. 1) Regulations 2026 (F2026L00093), reg 20(8), and explanatory statement · checked Nov 24, 2026
Capacity tiers
First 14 kWh of usable capacity at 100% of the factor, 14-28 kWh at 60%, 28-50 kWh at 15%; nothing above 50 kWh; total rounded down to a whole STCF2026L00093, reg 20(7) method statement · checked Nov 24, 2026
STC price
Clearing house price $40 per STC; spot prices 'remained close to the clearing house price of $40' throughout Q2 2026Clean Energy Regulator, Quarterly Carbon Market Report, June quarter 2026 · checked Nov 24, 2026

How the calculator works

Prices are the Essential Services Commission's Victorian Default Offer for 1 July 2026 to 30 June 2027, including GST, for each of the five distribution zones: the flat tariff and the new three-period time-of-use tariff (peak 4-9 pm, solar soak 11 am-4 pm, off-peak the other hours, every day). Victoria has had no minimum feed-in tariff since 1 July 2025, so the feed-in rate is yours to enter.

Usage defaults to 4,000 kWh a year, the ESC's representative home, split 29% peak, 18% solar soak and 53% off-peak, the ESC's reference proportions from AEMO residential load data for 2022-23 to 2024-25. Within each period usage is spread evenly by hour, and every day is the same.

Solar output is PVGIS (ERA5) hourly data for 2019-2023 at your nearest city, for panels facing north at 25 degrees with 14% losses: about 1,386 kWh per kW a year in Melbourne and 1,626 in Mildura. The calculator runs every day of those five years hour by hour: solar first covers the house, surplus charges the battery, the battery covers the house when the sun is not enough, and the rest is exported. Results are five-year averages.

Federal rebates use our STC calculators: the solar STCs by postcode zone and deeming year, and the Cheaper Home Batteries STCs by usable kWh and install period. Payback is the cost after rebates divided by the first-year saving.

Solar and batteries in Victoria: common questions

How much does solar save in Victoria in 2026?

For a Melbourne home using 4,000 kWh a year on CitiPower's flat Victorian Default Offer, a 6.6 kW system saves about $424 a year with no feed-in tariff, or about $800 with a 5c feed-in tariff. The saving is higher on dearer tariffs: about $523 a year on AusNet's flat tariff with no feed-in tariff.

Is a solar battery worth it in Victoria?

With 6.6 kW of solar and 4,000 kWh a year, a 13.5 kWh battery saves about $604 a year on CitiPower's flat tariff with no feed-in tariff, and about $475 with a 5c feed-in tariff. Divide the battery's cost after the federal rebate by that saving to get the payback; the calculator does it with your quote.

Is there a minimum feed-in tariff in Victoria?

No. The Essential Services Commission stopped setting minimum feed-in tariffs after an amendment to the Electricity Industry Act 2000; there has been none since 1 July 2025. Retailers set their own feed-in tariffs, which cannot be below zero.

Should I be on a flat or time-of-use tariff with solar and a battery?

It depends on your distributor. On the 2026-27 Victorian Default Offer, a home with 6.6 kW of solar and 4,000 kWh a year pays a little less on the flat tariff in the CitiPower area (about $1,056 against $1,076) but less on time of use in the AusNet area (about $1,197 against $1,225). With a 13.5 kWh battery covering the evening peak, the two tariffs come out about the same. The calculator shows both for your inputs.

Is a bigger battery better?

Not for an average home. With 6.6 kW of solar and 4,000 kWh a year, a 10 kWh battery saves about $594 a year and a 13.5 kWh battery about $604: the extra capacity sits unused most nights. Bigger batteries pay off for homes that use more in the evening and overnight.

Related

Newsletter

The weekly brief

Every Tuesday: the 5 stories that matter, India tender awards roundup, one chart we made. Free.