In one line
The solar power arriving on a surface per unit area, measured in watts per square metre — the input that determines how much a PV array can produce at any instant.
What it means
Irradiance is instantaneous power density from the sun. Energy professionals distinguish global horizontal irradiance (GHI, measured on a flat horizontal surface), direct normal irradiance (DNI, the beam component perpendicular to the sun), diffuse horizontal irradiance (DHI, scattered sky light), and plane-of-array irradiance (POA, what the tilted module actually sees). Yield models convert GHI and DNI into POA using tilt, azimuth, and a transposition model, then apply module and system losses. Irradiance is power (W/m²); accumulated over time it becomes irradiation or insolation (kWh/m²/day), which is the number used for annual energy estimates.
Worth knowing
- Irradiance is instantaneous power; irradiation (insolation) is energy accumulated over time.
- POA irradiance — not GHI — is what a tilted or tracked array actually converts.
- 1,000 W/m² is the reference used in Standard Test Conditions, not a typical field value.
- Clear-sky peaks can briefly exceed 1,200 W/m² through cloud-edge enhancement.
The four components you will see in a yield report
Any bankable yield study separates the resource into components because each behaves differently with tilt, tracking and weather.
- GHI — total on a horizontal plane; the headline resource number for a site.
- DNI — the beam component; the only component concentrating technologies can use, and the one trackers exploit most.
- DHI — scattered light; dominant on overcast days and the reason arrays still produce in monsoon conditions.
- POA — the transposed value on the actual module plane, after tilt, azimuth, row shading and ground reflection.
Field notes
- 1Compare sites on long-term GHI from a validated dataset, never on a single year of satellite data — interannual variation of ±5% is normal.
- 2Ask which transposition model produced the POA figure; different models can differ by 2–3% on the same GHI input.
- 3Pyranometers need cleaning and recalibration; a drifting sensor makes a healthy plant look underperforming.
Common mistakes
- Quoting GHI when the contract performance guarantee is written against POA — the two differ by 5–20% depending on tilt.
- Treating 1,000 W/m² as an expected operating condition rather than a laboratory reference point.
Frequently asked
What is the difference between irradiance and irradiation?
Irradiance is instantaneous power per unit area, measured in W/m². Irradiation (also called insolation) is irradiance accumulated over time, measured in kWh/m² — typically expressed per day or per year and used for energy yield estimates.
What irradiance do solar panels need to produce power?
Modules begin producing at very low light — around 20–50 W/m² — though inverters usually need a minimum DC voltage before they start exporting. Output scales close to linearly with irradiance across the normal operating range.